Door Interlock System

Door Interlock System

Part Number:DIS

Category:Door Control System

  • The Door Interlock System comprises of Door Controller, Door Stations, Electromagnetic Locks, Door Position Sensors and Power Supply unit
  • The Door Controller monitors the status of the Doors and controls the locking and release sequence of the Doors.
  • The Electromagnetic Locks are used to normally hold the Doors Locked.
  • The user can Request for Release of the Door by presenting hand in front of sensor on the Door Controller / Door Station.
  • The Door is released only if the interlocked Doors are in locked condition.
  • The Door Emergency Station is provided to override the Interlock logic and release all the doors and allow free passage during an Emergency event.
RLY
Contactless
Door Interlock
EML
📐Technical Specification
+Accesories
📥Document
📹Videos
📚Application Note
Parameter Description
Voltage 30VDC SELV , KNX
Maximum Current Consumption 15mAt
Connection Type Typical TP1 bus connector for 0.80mm Ø rigid cable
External power supply Not required
Operation temperature 0°C .. +55°C
Storage temperature -20°C .. +55°C
Operation humidity 5 .. 95% (Non-condensing)
Storage humidity 5 .. 95% (Non-Condensing)
Degree of protection IP20, clean environment
Installation Flush mount on standard 2M electrical box.
PCB CTI index 175V
Housing material ABS
Enclosure dimension (l x w x d mm) 90 x 90 x 26
Number of inputs 4
Inputs per common 4
Operation voltage +3.3VDC in the common
Operation current 5 mA @ 3.3VDC (per input)
Switching type Dry voltage contacts between input and common
Connection method Pluggable screw terminal block
Cable cross-section 0.2-1.5mm² (IEC) / 28-14AWG (UL)
Maximum cable length 30m
Image 1
Image 3
Image 2
📚 APPLICATION NOTES

Application

Description

Application Note Description of Application