Door Controller Model: Dor-2100 series
The Dor-2100 Controller is one of the key integrated components for Door Interlock Systems. It is an intelligent controller incorporating an 32 bit Micro-controller. The Dor-2100 is built to control one Door in Stand Alone Mode and can interlock up to 16 Doors when 16 Controllers are connected in Network on OSDP bus. The Dor-2100 controller logic ensures that the Doors are normally closed and are locked. Unlocking any door causes the interlocked door to be incapable of being unlocked and hence prevents simultaneous operation of doors. Multi-Level Logic allows configuring the system to interlock the Door with any number of Doors within the Door interlock group. This logic allows simultaneous use of the Change rooms and reduces hindrance to Man Movement.
- Compact design and elegant PC snap fit bezel.
- Contact Less operation.
- Easy Installation, minimum civil work and interconnecting cables.
- Mounting: directly on Door Frame.
- Integration facility with Access Control System to Restrict Man movement.
- Number of Doors Controlled: One.
- Built in Capacitive sensor for Door Release Request operation.
- Configurable as Master or Slave.
- Number of Doors Controlled: One.
- Inputs:
- Emergency Release: One
- Lock Feedback Input (LFB): One.
- Door Position Sensor Input (DPS): One.
- Configurable Auxiliary Input: One (for Integration with Fire alarm / other systems)
- Door Lock Outputs: Controls one 600 Lbs Electromagnet lock, 500 mA load max.
- Indications:
- Red LED Steady ---------> Door Locked
- Red LED Blink ---------> Access Denied / Interlocked
- Green LED Steady --------->Door Released
- Orange LED Blinking ---------> Door is not Locked
- Red LED Blink & Green Led Blink ---------> Emergency
- Communication:
- Port 1: RS-485 port, OSDP
- Port 2: Mini USB Port, for configuration of controller.
Alarms
Propped Door Alarm: The Sounder activates when the door is unlocked/ open for more than
20 seconds. : Intermittent Beeps.
Forced Door Alarm: The Sounder activates when the door is forced open, without the operation
of Door Release Button. Continuous Beep.
Emergency Alarm: The sounder activates when Emergency situation is initiated. Intermittent Beeps
with indications.
Door not locked alarm: The sounder activates when the door is not properly locked.
Door Operation Modes
- Access Denied local - Door is permanently locked when auxiliary input is momentarily activated and remains in lock condition until reset with second momentary signal.
- Access Denied global - All Door in the system are permanently locked when auxiliary input is momentarily activated and remains in lock condition until reset with second momentary signal.
- Free Access local - Door is unlocked when auxiliary input is activated and resets only after auxiliary input is deactivated.
- Free Access global - All doors in system are unlocked when auxiliary input is activated and resets only after auxiliary input is deactivated.
- Emergency - All doors in system are unlocked and audio-visual alarm is activated.
Timers
- Door Release Timer (DRT) : The time for which the door to be in release condition when a valid
external request (Door Release) or internal command (Cap sense Proximity is detected) is
available.Default time is 5 seconds and can be configured using configuration utility. - Egress Time Delay (ETD) : The time delay duration between the request to release door
command and releasing of the door. Default time is 0 seconds and can be configured using
configuration utility. - Interlock Time Delay (ITD) :The time delay duration between the next release of the door after
the previous release of the interlocked doors. Default time is 0 seconds and can be configured
using configuration utility. - Lock Time Delay (LTD) : The time delay duration between Doors return to close condition and
Lock energizing. Default time is 0 seconds and can be configured using configuration utility.
Electrical & Mechanical
- Operating voltage:12-24V DC.
- Size: 36mm (w) x 145 mm (h) x 14mm (d)